Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

THERMODYNAMIC STEAM TRAPS DT40/2

  • Overview
  • Description
  • Main Features
•  Available Sizes : 3/8” to 1” – DN 10 to DN 25
•  Connections : Female screwed ISO7/1 Rp (BS21). Flanged EN1092-1 PN40 or ANSI.
Body Material : CF8 / 1.4308
•  Gasket : Stainless St. / Graphite
•  Installation : Horizontal installation recommended.Can be installed in any position.
Application limits : Min. working pressure – 0,25 1,5 bar. Max.working back pressure – 80%
•  PS-Operating P. :  
•  TS-Operating T. :  
The thermodynamic DT40/2 disc steam traps are compact and lightweight-easy to install traps, excellent for high pressure systems, including steam tracing applications. The insulation cover ensures a consistent operation and makes it particularly suitable for those applications where the weather conditions, such as rain and wind, may affect the normal operation. These traps have only one moving part and offer a wide operating range, without adjustment. Connections are female screwed or flanged. Intermittent discharge. Operates on superheated steam. The seat and disc can be easily replaced in field without removing the trap from the line. Unaffected by water hammer and vibrations. Built-in easy-to-clean strainer
Insulation cover
Blowdown valve

 

BIMETALLIC STEAM TRAPS

  • Overview
  • Description
  • Main Features
•  Available Sizes : 1/2” to 5” ; DN 40 to DN 125  
•  Connections : Flanged EN 1092-1 or ANSI
Body Material : CF8 / 1.4308, Stainless Steel
•  Gasket : Vertical installation
•  Installation :  
Application limits : Tri-Clamp ends CF3M / 1.4409
•  PS-Operating P. : Up to 63 bar
•  TS-Operating T. : Up to 300 ΊC.
The BM series bimetallic steam traps and air eliminators are simple and robust traps, recommended for large process applications. They can be supplied with several bimetallic regulators achieving the requested flow rate. Connections are flanged as standard (others on request). Modulating discharge.
Discharges condensate below steam temperature.
Excellent air discharge.
Operates on superheated steam.
Unaffected by water hammer and vibrations

FLOAT AND THERMOSTATIC STEAM TRAPS

  • Overview
  • Description
  • Main Features
•  Available Sizes : 1/2” to 3” – DN 15 to DN 50  
•  Connections : Flanged EN 1092-1 PN16 or ANSI
Body Material : CF8 / 1.4308, Stainless Steel/GJS-400-15 / 0.7040
•  Gasket : Stainless steel / Graphite
•  Installation : Horizontal standard installation
Application limits :
•  PS-Operating P. : 4,5BAR-10 BAR-14 BAR
•  TS-Operating T. :
The FLT float and thermostatic (integral air vent) steam traps series are designed for all types of low and high pressure steam heating and process equipment. Typical applications include unit heaters, heat exchangers, driers, jacketed vessels and all the applications where continuous drainage is essential. Connections are female screwed or flanged for horizontal or vertical installation Modulating discharge. Unaffected by sudden or wide load and pressure changes.
Discharges condensate at steam temperature.
Excellent air discharge (by thermostatic air vent).

INVERTED BUCKET STEAM TRAPS

  • Overview
  • Description
  • Main Features
•  Available Sizes : 1/2" to 3/4”
•  Connections : Female screwed ISO7/1 Rp (BS21)
Body Material : CF8 / 1.4308, Stainless Steel/GJS-400-15 / 0.7040
•  Gasket : Stainless steel / Graphite
•  Installation : Horizontal installation , Vertical installation(IB30S
Application limits :
•  PS-Operating P. : 4BAR-8 BAR-12 BAR
•  TS-Operating T. :
The IBseries inverted bucket steam traps are recommended for applications where the most important requirements are overall operating efficiency and long, trouble-free service life. They operate intermittently, either wide open or tightly closed and are, therefore, best suited for medium and high steam pressure applications. Connections are female screwed for horizontal installation.
Intermittent discharge.
Discharges condensate at steam temperature.
Unaffected by water hammer and vibrations.
Easy to maintain.

STEAM TRAPS & AIR ELIMINATORS

  • Overview
  • Description
  • Main Features
•  Available Sizes : 1/4” to 2”; DN 15 to DN 50
•  Connections : Female screwed ISO 7/1 Rp (BS21)
Body Material : Brass EN 12165 / CuZn39Pb2, Stainless Steel
•  Gasket : Stainless steel / Graphite
•  Installation : Vertical installation (TH13, TSS22), Horizontal (TH21 ,)TH21SS
Connection :
•  PS-Operating P. : 13
•  TS-Operating T. : 100
The TH series thermostatic steam traps and air eliminators are specifically designed for use on process equipment such as kettle cookers, sterilizers, food, chemical and laundry equipment. Their small size makes them ideal for use with a wide variety of this equipment and specially as air eliminator. Connections are female screwed.Built-in strainer.
Modulating discharge.
Discharges condensate close to steam temperature.
Thermostats for different sub cooling (5 ΊC to 30 ΊC).
Simple and compact design.
Excellent air discharge.
Logo FDA iso flag

 

 

 

 

We offer a full range of T-316L stainless steel clean steam thermostatic traps to handle the special requirements of clean steam systems. Different body configurations allow choice of piping and ease of cleaning. The thermostatic design is free-draining and can operate close to steam temperature at any given pressure..